Back to AI News
arxiv

ReuScope: Auditing Data Reuse and Evaluation Sensitivity in Capsule Vision 2024

ReuScope is a protocol for auditing data reuse and evaluation sensitivity, applied to the Capsule Vision 2024 challenge. It reveals byte-identical files crossing the public training-validation boundary and shared source recordings between partitions. Removing Kvasir-Capsule training rows drops public-validation balanced accuracy from 82.5% to 61.2%, but the effect reverses on other sources, indicating sensitivity rather than leakage inflation. The protocol distinguishes observed reuse from conditional performance sensitivity with matched controls and uncertainty intervals.

AI Brief

Provides a rigorous method to audit data leakage and evaluation robustness in medical imaging benchmarks, offering practical insights for challenge organizers and researchers.

arXiv:2610.41835v1 Announce Type: new Abstract: We develop ReuScope, a protocol for auditing data reuse and evaluation sensitivity, using Capsule Vision 2024 as a case study. It combines measurements of data relationships with two comparisons: changing the evaluation population while holding predictions fixed, and changing training data while holding evaluation fixed. Byte-identical files cross the public training-validation boundary, and all 41 Kvasir-Capsule recordings that contribute frames occur in both partitions. Shared source recordings establish cross-split overlap; missing cross-recording patient identifiers prevent counting unique shared patients. Across ten paired seeds, removing all training rows attributed to Kvasir-Capsule, plus five rows from other sources flagged as near-matches to it, lowers public-validation balanced accuracy from 82.5% to 61.2%. Evaluating the same fitted models on the validation rows of the other sources reverses the comparison: removal improves balanced accuracy by 1.38 percentage points. The public-validation drop measures sensitivity to source removal, not an amount of leakage-induced inflation. Matched controls show that sample size and class counts alone do not explain the observed score differences. An exploratory experiment removes the training neighbors of validation frames that have close training matches, or equally many distant training rows, and yields a difference-in-differences estimate, relative to matched unflagged frames, of -0.355 percentage points in true-class probability; the paired-t interval for accuracy spans zero. The resulting procedure distinguishes observed reuse from conditional performance sensitivity and specifies the population, class support and uncertainty unit for each conclusion.
Be the first to rate this article.

Comments & Questions (0)

Captcha
Please be respectful — let's keep the conversation friendly.

No comments yet

Be the first to comment!