CtrlCT toolkit benchmarks anatomical control in Text-to-CT generators

Researchers propose CtrlCT, a toolkit for evaluating Text-to-CT generators on Credibility (population-level realism versus real CTs and reports) and Control (metamorphic tests that edit a report at fixed seed to check requested changes, absent negated findings, and limited distant-anatomy shifts). Benchmarking five public generators on 940 chest CTs and 687 edits of pleural effusion and cardiomegaly, with a sixth generator held out to test the toolkit, reveals a trade-off: the most credible generators barely respond to an added effusion, while the most responsive produce less realistic and less diverse CTs. The authors say existing literature analyses do not reveal this tension. CtrlCT, its edits, seeds, and 30,525 synthetic CTs are to be released after acceptance.

AI Brief

It provides a concrete benchmarking toolkit and empirical evidence that current Text-to-CT generators face a credibility-versus-control trade-off, which matters for medical image synthesis evaluation.

arXiv:2611.33003v1 Announce Type: cross Abstract: Recent advances in deep learning and the public availability of computed tomography (CT) datasets with paired reports have enabled many Text-to-CT generators. However, their evaluations almost always differ in preprocessing and metrics, which hinders comparison. Moreover, their protocols almost never test how editing the report changes the CT, not even at the same seed, so the report is often assumed to control the anatomy without evidence of how much and how consistently it does. We therefore propose CtrlCT, a toolkit that tests two properties of a generator, Credibility and Control. Credibility tests compare generated CTs, as a population, with real CTs and reports; Control tests are metamorphic and need no reference CT: at a fixed seed, editing one finding should change it as requested, keep negated findings absent and shift distant anatomy no more than a new seed, and the change should hold across seeds. A Report Card summarises all measures and insights for each generator. We benchmark five public generators on 940 chest CTs and 687 edits of pleural effusion and cardiomegaly, holding out a sixth to test the toolkit. Among them, the most credible generators barely respond to an added effusion, while the most responsive produce less realistic and less diverse CTs. The analyses proposed in the literature do not reveal this. We release CtrlCT, its edits, seeds and 30,525 synthetic CTs after acceptance.
Be the first to rate this article.

Comments & Questions (0)

Captcha
Please be respectful — let's keep the conversation friendly.

No comments yet

Be the first to comment!