Adult-to-Pediatric Fine-Tuning Improves ECG Foundation Model Performance
Researchers adapted an adult ECG foundation model to pediatric ECGs using 339,563 12-lead recordings from 238,189 children, comparing direct transfer, pediatric fine-tuning, and training from scratch. Pediatric fine-tuning achieved a mean AUC of 0.9695, above direct transfer at 0.8256 and de novo training at 0.9661, and reached 0.9079 using only 1% of training data. On 10,999 external ECGs, fine-tuning achieved a mean AUC of 0.9385 across 30 labels and also generalized to age regression and congenital heart disease classification. In a study with 17 clinicians and 100 cases, diagnostic accuracy rose from 56.8% to 65.4% and did not decline when the AI erred.
It provides concrete evidence that adult ECG foundation models need pediatric adaptation and that fine-tuning is a data-efficient route to scalable pediatric ECG AI.
Comments & Questions (0)
No comments yet
Be the first to comment!